//以下代码放在head标记结尾的前面 Update cookies preferences

T960

Automatic Titrator
The titrator is a high-precision laboratory experimental analysis instrument that uses potentiometric, dead-stop, Karl Fischer, and other titration methods for capacity analysis. It can perform acid-base titration, redox, precipitation, complexation, dead-stop, Karl Fischer moisture, etc. It has the functions of constant titration, micro titration, end point setting titration, volume setting titration and mode titration, etc. At the same time, it can choose or build its own special titration mode according to the actual needs of users.

Hanon T960 series of products can be used in food, drug inspection, disease control, inspection, commodity inspection, water treatment, petroleum, chemical, marine, electric power, environmental protection, new energy, teaching, scientific research, and other fields.

    Specifications

    T960 Basic

    T960 Pro

    Titration module

    Potentiometric

    Potentiometric, Dead-stop

    mV Measuring range:

    -2000.0mV+2000.0mV

    mV Measuring:

    Resolution: 0.1mV,

    Accuracy: 0.1mV±0.03%

    pH Measuring range:

    -20.000pH+20.000pH

    pH Measuring:

    Resolution: 0.001pH

    Accuracy: 0.003pH

    Temp.Measuring range:

    -5120℃

    Temp. Accuracy:

    ±0.1℃

    Maximum number of titration modules

    4 (2 modules in the standard package)

    Maximum number of simultaneous filling modules:

    4 (2 modules in the standard package)

    Burette optional

    1mL 5mL 10mL 25mL(10ml burette in the standard package )

    Burette resolution

    1/1500000

    Burette refill time:

    16 seconds (100% filling speed)

    User grading management system

    3 level (Customizable operation permissions)

    Audit trail

    Controlled by

    PC

    WiFi module

    Stirring

    Magnetic stirring, upper stirring (optional)

    Electrode interface type:

    mV/pH measuring electrode interface, reference electrode interface,

    mV/pH measuring electrode interface, reference electrode interface,

    PT1000 temperature electrode interface

    PT1000 temperature electrode interface, polarized electrode interface

    Autosampler (Optional)

    Equipped with 1 independent analysis station, optional 16-position 100mL autosampler, 12-position 250mL autosampler, and 18-position 50mL autosampler